• English English

Categories

Contact Info

Tel:  0086-25-84055220, 
      0086-25-66920771      
Fax:  0086-25-84055220
Email: info@orchid-med.com
       orchidmed@foxmail.com
   

  • orchidmed@hotmail.com-Click To Talk
  • orchidmed-Click To Talk
  • sales@orchid-med.com-Send Email to me!

Syringe Pump ORC-500



 

1. 4.3'' Large LCD screen, with different colors show.
2. With LCD backlight, can use in various lighting conditions.
3. Time display, convenience for show and time memory.
4. Simultaneous display: Time, Battery, Injection State, Mode, Speed, Injection volume and time, Syringe Size, Alarm sound, Block, Accuracy, Body weight, Drug, dose and liquid amount
5. Remote control function, can adjust speed, time, volume and drug amount directly, easier operation, save doctor and nurse's time
6. Advanced technology, mainly based on Linux system, more safe and steady. All technical are designed by ourself, further update is avaiable.
7. Multi injection modes: V mode, T mode, and body weight mode
8. Alarm: including all abnormal conditions alarm system, with visible, audible and details show on the screen.
Technical Specification
Rate Range
50ml syringe : 0.1~1800ml/h    (0.1~999.9ml/h step :0.1ml/h
30ml syringe :0.1~900ml/h       1000~1800ml/h step : 1ml/h)
20ml syringe :0.1~600ml/h
10ml syringe :0.1~300ml/h
5 ml syringe :0.1~150ml/h
Volume Limit
0.1~1999.9ml(step: 0.1ml)
Accumulated Volume
9999.9ml(step: 0.1ml)
Accuracy
Within±2%
Purge Rate
50ml syringe: 1800ml/h (Bolus rate:   1200ml/h)
30ml syringe:900ml/h   (Bolus rate:   600ml/h)
20ml syringe:600ml/h   (Bolus rate:    400ml/h)
10ml syringe:300ml/h   (Bolus rate:    200ml/h)
5 ml syringe:150ml/h   (Bolus rate:    100ml/h)
Alarm
Liquid volume nearly alarm, Liquid Injection Finished Alarm, Doses injection finished Alarm, Occlusion Alarm, syringe off Alarm, syringe non-installed correctly alarm, Low battery alarm, Power off Alarm
s
Occlusion
Three levels for Occlusion: High, Middle, Low
KVO Rate
0.1~5ml/h (adjustable,  step: 0.1 ml/h)
Fuse
 F1AL/250V("F"indicate fast, low breaking capacity), 2 pcs(installed inside pump).
Power supply
100~220V,50Hz, Built in Rechargeable battery, 11.1V,Capacity ≥2000mAh;After charging 10 hours, it can work at 5ml/h(GB 9706.27-2005 average rate)about 4 hours.
Working Surrounding
Temperature:﹢5℃~+40℃
Humidity:20%~ 90%
Storage Surrounding
Temperature :﹣30℃~﹢55℃
Humidity : ≤95%
Atmosphere Pressure
860hPa~1060hPa
Safe Class
I Type CF devices , Internal Battery, Intermittent Load Continuous working
Size
282mm(L)×210mm(W)×148mm(H)
Weight
2.2Kg
Accessories
Pump, Remote Controller, Power line, user manual, Guarantee card, Certificate

1. 4.3'' Large LCD screen, with different colors show.

2. With LCD backlight, can use in various lighting conditions.

3. Time display, convenience for show and time memory.

4. Simultaneous display: Time, Battery, Injection State, Mode, Speed, Injection volume and time, Syringe Size, Alarm sound, Block, Accuracy, Body weight, Drug, dose and liquid amount

5. Remote control function, can adjust speed, time, volume and drug amount directly, easier operation, save doctor and nurse's time

6. Advanced technology, mainly based on Linux system, more safe and steady. All technical are designed by ourself, further update is avaiable.

7. Multi injection modes: V mode, T mode, and body weight mode

8. Alarm: including all abnormal conditions alarm system, with visible, audible and details show on the screen.

Technical Specification

Rate Range

50ml syringe : 0.1~1800ml/h    (0.1~999.9ml/h step :0.1ml/h

30ml syringe :0.1~900ml/h       1000~1800ml/h step : 1ml/h)

20ml syringe :0.1~600ml/h

10ml syringe :0.1~300ml/h

5 ml syringe :0.1~150ml/h


Volume Limit

0.1~1999.9ml(step: 0.1ml)


Accumulated Volume

9999.9ml(step: 0.1ml)


Accuracy

Within±2%


Purge Rate

50ml syringe: 1800ml/h (Bolus rate:   1200ml/h)

30ml syringe:900ml/h   (Bolus rate:   600ml/h)

20ml syringe:600ml/h   (Bolus rate:    400ml/h)

10ml syringe:300ml/h   (Bolus rate:    200ml/h)

5 ml syringe:150ml/h   (Bolus rate:    100ml/h)

 

Alarm

Liquid volume nearly alarm, Liquid Injection Finished Alarm, Doses injection finished Alarm, Occlusion Alarm, syringe off Alarm, syringe non-installed correctly alarm, Low battery alarm, Power off Alarm

s

Occlusion

Three levels for Occlusion: High, Middle, Low


KVO Rate

0.1~5ml/h (adjustable,  step: 0.1 ml/h)


Fuse

 F1AL/250V("F"indicate fast, low breaking capacity), 2 pcs(installed inside pump).


Power supply

100~220V,50Hz, Built in Rechargeable battery, 11.1V,Capacity ≥2000mAh;After charging 10 hours, it can work at 5ml/h(GB 9706.27-2005 average rate)about 4 hours.


Working Surrounding

Temperature:﹢5℃~+40℃

Humidity:20%~ 90%

 

Storage Surrounding

Temperature :﹣30℃~﹢55℃

Humidity : ≤95%



Atmosphere Pressure

860hPa~1060hPa


Safe Class

I Type CF devices , Internal Battery, Intermittent Load Continuous working


Size

282mm(L)×210mm(W)×148mm(H)


Weight

2.2Kg


Accessories

Pump, Remote Controller, Power line, user manual, Guarantee card, Certificate

 

Copyright © 2004- ORCHID MEDICAL All Rights Reserved.