• English English

Categories

Contact Info

Tel:  0086-25-84055220, 
      0086-25-66920771      
Fax:  0086-25-84055220
Email: info@orchid-med.com
       orchidmed@foxmail.com
   

  • orchidmed@hotmail.com-Click To Talk
  • orchidmed-Click To Talk
  • sales@orchid-med.com-Send Email to me!

500mA 500mA X ray Radiograph Machine


* This machine is used to photograph patient’s esophagus, chest, gastrointestinal, abdomen, limbs etc for common radiography, Beam Limiting Device radiograph and high KV radiography.

More details


 

1. Anti-electroshock, radiation-proof, and full wave commutation. 
2. With electromagnetism controlling system, fluctuation bed board 
    and manual operation pillar to ensure a fast and reliable 
    location.  
3. Structure designed based on anthropotomy, with beautiful 
    appearance, and easy to operate. 
4. Convenient to take stretcher photograph.  
5. A sternum plank is optional (grid density: 40L/cm; grid ratio: 
   10:1; focus distance: 120cm;stationary, dimension: 15″×18″, 
   and distance adjustable)

 

Features:

1. Anti-electroshock, radiation-proof, and full wave commutation. 

2. With electromagnetism controlling system, fluctuation bed board and manual operation pillar to ensure a     fast and reliable  location.  

3. Structure designed based on anthropotomy, with beautiful appearance, and easy to operate. 

4. Convenient to take stretcher photograph.  

5. A sternum plank is optional (grid density: 40L/cm; grid ratio: 10:1; focus distance: 120cm;stationary,             dimension: 15″×18″, and distance adjustable)

Specifications:

 Power Output                     : 40KW                      
 X-ray Tube                          : Rotary anode 
 Focus                                  : 1.0mm
 Thermal Capacity              : 140 KJ 
 Commute Method             : Full Wave Commutation 
 Tube Voltage                      : 50
125KV,interval 1KV 
 Tube Current                     : 32mA(min) 
500 mA (max) Adjustable with different grades 
 Exposure Time                  : 0.020s
4.000s(23 grades) 
 Bucky grid                           : Grid Density                 : 40L/cM
                                                 Grid Ratio                      : 10:1
                                                 Focus Distance            : 120cm
                                                 Stationary Dimension : 15″×18″ 
Power Supply                    : Two Phases with Four Lines(380V±10
,50Hz Inner-resistance≤0.3Ω Capacity
                                               ≥40KVA) 
Structure 
    Bed Size                             : 2000×760mm 
    Bed Height                         : ≤700mm 
    Bed Transverse Movement Distance                    : ±110mm 
    Bed Longitudinal Movement Distance                  : ±450mm 
    Cassette Movement Distance                                : ≥500mm 
    X-ray Generator Revolution around Pillar Center: ±90° 
    Pillar Turning                                                              : 40°×9° 
    Pillar Movement Range along Bed                        : ≥1300mm 
    Distance Between Focus and Film(SID)              : 500
1280mm 
    Time Limit of Collimator Lamp                               : 15sec 
    Vertical Movement of Sternum Plank                     : 480
1460mm 
    Film Size                             : 5"×7"
14"×17"
Bed                                  :2200mm×1100mm×900mm        N.W. 300kgs  G.W.425kgs
Oil trunk                        :800mm×700mm×1050mm         N.W. 300kgs  G.W.375kgs
Operation   table            :1200mm×1000mm×1700mm     N.W. 350kgs  G.W.450kgs
Bucky stand                     :2440mm×1100mm×900mm     N.W. 250kgs  G.W.375kgs 

 

 