8" Patient Monitor ORC-6000B



 

●  8" color TFT LCD screen, resolution 800*600 
●  Waterproof design, resistance to dropping (1 meter) 
●  Low power consumption, fanless structure which 
     creates no noise
● Support external 13-20V DC power, continuously working 
     for 5.5 hours above on battery backup, full charge with 2.5 
     hours, suitable for Ambulance, Emergency Transport
●  Display mode: Big font, trends review, 7 leads ECG waveform 
      on same screen, and etc 
●  15 kinds of arrhythmia analysis, 15 kinds of drug concentration 
      analysis
●  Anti-electrosurgical unit (300W), anti-defibrillation (360J), 
      suitable for Operating Room, General Ward
●  Digital SpO2 technology, excellent anti- interference 
      performance, low perfusion (0.1%)
ECG
Lead: Standard 3/5 lead
Lead Mode: 5 Leads (RA, LA, LL, RL,V) 
Lead Selection: I, II, III, avR, avL, avF, V
Lead Mode: 3 Leads (RA, LA, LL) 
Lead Selection: I, II, III,
Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV
HR and Alarm Range: 
        Adult: 15 ~ 300 bpm
        Ped/Neo: 15 ~ 350 bpm
Accuracy: ±1% or±1bpm, which is greater
Resolution: 1 bpm 
Sensitivity: > 200 (uVp-p) 
Differential Input Impedance: > 5 MΩ
Bandwidth: 
        Surgery    1 ~ 20 Hz
        Monitor     0.5 ~ 40 Hz
        Diagnostic  0.05 ~ 130 Hz
CMRR: 
        Monitor > 100 dB 
        Operation > 100 dB 
        Diagnosis > 90 dB
Electrode Offset Potential: ±300mV 
Range: ±2 mV ~ ±700 mV
Width: 0.1 ms ~ 2 ms
Rise time: 10 us ~ 100 us
ST Segment Monitoring Range: 
        Measurement Range: -2.0 ~ +2.0 mV
        Measurement Accuracy: -0.8 ~ +0.8 mV
        Measurement Error: ±0.02 mV or ±10%
RESP
Method: Impedance Between RA-LL or RA-LA
Measuring Impedance Range: 0.3~3 Ω
Base line Impedance Range: 200~4 KΩ
Bandwidth: 0.1~2.5Hz
Resp. Rate: 
        Measuring and Alarm Range:
            Adult: 2 ~ 120 BrPM 
            Neo/Ped: 2 ~ 150 BrPM 
            Resolution: 1 BrPM 
            Accuracy: ±2 BrPM
            Apnea Alarm: 10 ~ 40 S
NIBP 
Method: Oscillometric
Mode: Manual, Auto, STAT                        
Measuring Interval in Auto Mode: 
        1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)
Measuring Period in STAT Mode: 5 Min
Pulse Rate Range: 40 ~ 240 bpm
Measuring and Alarm Range: 
        Adult Mode
            SYS 40 ~ 270 mmHg 
            DIA 10 ~ 215 mmHg 
            MEAN 20 ~ 235 mmHg                       
        Pediatric Mode
            SYS 40 ~ 200 mmHg 
            DIA 10 ~ 150 mmHg 
            MEAN 20 ~ 165 mmHg
        Neonatal Mode
            SYS 40 ~ 135 mmHg 
            DIA 10 ~ 100 mmHg 
            MEAN 20 ~ 110 mmHg
Static Pressure Range: 0 ~ 300 mmHg
Static Pressure Accuracy: ±3mmHg
Accuracy: Maximum Average Error ±5mmHg
                  Maximum Standard Deviation ±8mmHg
Overpressure Protection: 
        Adult Mode: 300 mmHg 
        Pediatric Mode: 240 mmHg 
        Neonatal Mode: 150 mmHg
SpO2
Measuring Range: 0 ~ 100 % 
Resolution: 1 %
Accuracy: 70% ~ 100%  ±2 %
                  0% ~ 69% unspecified
Pulse Rate: 
        Measuring Range: 20~300 bpm
        Resolution: 1bpm
        Accuracy: ±3bpm
TEMP
Applicable Temperature Sensor: YSI, CYF
Channel: 1
Measuring Range: 0 ~ 50 ℃
Resolution: ±0.1 ℃
Accuracy: ±0.1 ℃ (Do not including sensor error)
Dimension: 210*80*175mm (L*W*H)
Weight: 1.35kg
Standard: 3/5-Lead ECG, RESP, SpO2, NIBP, PR, 1-TEMP
Optional: Mainstream/Sidestream EtCO2, Touch screen

●  8" color TFT LCD screen, resolution 800*600 

●  Waterproof design, resistance to dropping (1 meter) 

●  Low power consumption, fanless structure which creates no noise

●  Support external 13-20V DC power, continuously working for 5.5 hours above on     battery backup, full charge with 2.5 hours, suitable for Ambulance, Emergency       Transport

●  Display mode: Big font, trends review, 7 leads ECG waveform on same screen,       and etc 

●  15 kinds of arrhythmia analysis, 15 kinds of drug concentration 

      analysis

●  Anti-electrosurgical unit (300W), anti-defibrillation (360J), 

      suitable for Operating Room, General Ward

●  Digital SpO2 technology, excellent anti- interference 

      performance, low perfusion (0.1%)

 

ECG

Lead: Standard 3/5 lead

Lead Mode: 5 Leads (RA, LA, LL, RL,V) 

Lead Selection: I, II, III, avR, avL, avF, V

Lead Mode: 3 Leads (RA, LA, LL) 

Lead Selection: I, II, III,

Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV

HR and Alarm Range: 

        Adult: 15 ~ 300 bpm

        Ped/Neo: 15 ~ 350 bpm

Accuracy: ±1% or±1bpm, which is greater

Resolution: 1 bpm 

Sensitivity: > 200 (uVp-p) 

Differential Input Impedance: > 5 MΩ

Bandwidth: 

        Surgery    1 ~ 20 Hz

        Monitor     0.5 ~ 40 Hz

        Diagnostic  0.05 ~ 130 Hz

CMRR: 

        Monitor > 100 dB 

        Operation > 100 dB 

        Diagnosis > 90 dB

Electrode Offset Potential: ±300mV 

Range: ±2 mV ~ ±700 mV

Width: 0.1 ms ~ 2 ms

Rise time: 10 us ~ 100 us

ST Segment Monitoring Range: 

        Measurement Range: -2.0 ~ +2.0 mV

        Measurement Accuracy: -0.8 ~ +0.8 mV

        Measurement Error: ±0.02 mV or ±10%



RESP

Method: Impedance Between RA-LL or RA-LA

Measuring Impedance Range: 0.3~3 Ω

Base line Impedance Range: 200~4 KΩ

Bandwidth: 0.1~2.5Hz

Resp. Rate: 

        Measuring and Alarm Range:

            Adult: 2 ~ 120 BrPM 

            Neo/Ped: 2 ~ 150 BrPM 

            Resolution: 1 BrPM 

            Accuracy: ±2 BrPM

            Apnea Alarm: 10 ~ 40 S



NIBP 

Method: Oscillometric

Mode: Manual, Auto, STAT                        

Measuring Interval in Auto Mode: 

        1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)

Measuring Period in STAT Mode: 5 Min

Pulse Rate Range: 40 ~ 240 bpm

Measuring and Alarm Range: 

        Adult Mode

            SYS 40 ~ 270 mmHg 

            DIA 10 ~ 215 mmHg 

            MEAN 20 ~ 235 mmHg                       

        Pediatric Mode

            SYS 40 ~ 200 mmHg 

            DIA 10 ~ 150 mmHg 

            MEAN 20 ~ 165 mmHg

        Neonatal Mode

            SYS 40 ~ 135 mmHg 

            DIA 10 ~ 100 mmHg 

            MEAN 20 ~ 110 mmHg

Static Pressure Range: 0 ~ 300 mmHg

Static Pressure Accuracy: ±3mmHg

Accuracy: Maximum Average Error ±5mmHg

                  Maximum Standard Deviation ±8mmHg

Overpressure Protection: 

        Adult Mode: 300 mmHg 

        Pediatric Mode: 240 mmHg 

        Neonatal Mode: 150 mmHg



SpO2

Measuring Range: 0 ~ 100 % 

Resolution: 1 %

Accuracy: 70% ~ 100%  ±2 %

                  0% ~ 69% unspecified

Pulse Rate: 

        Measuring Range: 20~300 bpm

        Resolution: 1bpm

        Accuracy: ±3bpm




TEMP

Applicable Temperature Sensor: YSI, CYF

Channel: 1

Measuring Range: 0 ~ 50 ℃

Resolution: ±0.1 ℃

Accuracy: ±0.1 ℃ (Do not including sensor error)


Dimension: 210*80*175mm (L*W*H)


Weight: 1.35kg


Standard: 3/5-Lead ECG, RESP, SpO2, NIBP, PR, 1-TEMP

Optional: Mainstream/Sidestream EtCO2, Touch screen

 