• English English

Categories

Contact Info

Tel:  0086-25-84055220, 
      0086-25-66920771      
Fax:  0086-25-84055220
Email: info@orchid-med.com
       orchidmed@foxmail.com
   

  • orchidmed@hotmail.com-Click To Talk
  • orchidmed-Click To Talk
  • sales@orchid-med.com-Send Email to me!

Vital Sign Monitor ORC-3000F


Vital Signs Monitor(NIBP/SPO2/TEMP)

More details


 

Unique outline design, skillful and portable  
Clear and bright color LCD with real time display and large LED display values
Intelligent Measuring of NIBP/SpO2/PR/PLETH/TEMP
Storage/Review trend data up to 129 hours and 3888 groups 
Audio and visual alarm
Built-in rechargeable Li-ion battery, up to 4-hour power supply
Automatic shutdown for power saving
Unique Tele-monitoring and Synchronization retransmit function 
Utility PC software package for long time real time monitoring, web transferring, history data uploading/review/print/storage.
Technical Specifications
1. General Specifications:
Size: 300mm×183mm×99mm
Net Weight: 1110g
Display Specification
Measurement Display: color LCD screen & LED
Power Supply Indicator: Dual-color LED (red/green)
Classification:BF type applied part
2. Power Supply
AC Power Adaptor:
Input: 100~240VAC, 50/60Hz
Output: DC 5V, 2A
Battery:
Li-ion rechargeable battery, 3.7V, 3AHr
Operating Time: 4 hours with full battery capacity.
(Condition: 25℃, NIBP working period is 10 minutes)
Recharge Time: 8 hours
3. Environment
Temperature
Working:0~45C
Transport and Storage: -25~85C
Humidity
Working:15 ~95 %
Transport and Storage: 10 ~95 % (no condensation)
4. Monitoring Parameter
SpO2 
Measurement object: Adult, Pediatric, Neonate
SpO2%
Measuring Range:0~100%
Resolution:1 %
Accuracy:2 %(90~99%), 3 %(70~89%),unspecified (0~69%)
Pulse Rate 
Measuring and Alarm Range:30~250bpm
Resolution: 1bpm
Accuracy: 1bpm
NIBP 
Measurement object: Adult, Pediatric
Method: Oscillometric
Mode: Manual, Auto, STAT
Measuring Interval in AUTO Mode: 1, 2, 3, 5, 10, 15, 20, 30, 45, 60 (min)
Measuring Period in STAT Mode: 5 min
Cuff Pressure Range:0 ~300mmHg
Pulse Rate Range:30~250bpm
Measurement Rage: Adult 30~255mmHg, Pediatric 30~160mmHg
Over-pressure Protection: Adult 300mmHg, Pediatric 220mmHg
Pressure Resolution : 1mmHg
Temperature
Input: Body surface thermal-sensitive resistor temperature sensor
Measuring Range: 0~50℃
Accuracy: 0.1℃
5. Storage and Review 
Maximum Data Quantity: 3888 groups

*Unique outline design, skillful and portable  

*Clear and bright color LCD with real time display and large LED display values

*Intelligent Measuring of NIBP/SpO2/PR/PLETH/TEMP

*Storage/Review trend data up to 129 hours and 3888 groups 

*Audio and visual alarm

*Built-in rechargeable Li-ion battery, up to 4-hour power supply

*Automatic shutdown for power saving

*Unique Tele-monitoring and Synchronization retransmit function 

*Utility PC software package for long time real time monitoring, web transferring, history data uploading/review/print/storage.


Technical Specifications


1. General Specifications:

Size: 300mm×183mm×99mm

Net Weight: 1110g

Display Specification

Measurement Display: color LCD screen & LED

Power Supply Indicator: Dual-color LED (red/green)

Classification:BF type applied part


2. Power Supply

AC Power Adaptor:

Input: 100~240VAC, 50/60Hz

Output: DC 5V, 2A

Battery:

Li-ion rechargeable battery, 3.7V, 3AHr

Operating Time: 4 hours with full battery capacity.

(Condition: 25℃, NIBP working period is 10 minutes)

Recharge Time: 8 hours


3. Environment

Temperature

Working:0~45C

Transport and Storage: -25~85C

Humidity

Working:15 ~95 %

Transport and Storage: 10 ~95 % (no condensation)


4. Monitoring Parameter

SpO2 

Measurement object: Adult, Pediatric, Neonate

SpO2%

Measuring Range:0~100%

Resolution:1 %

Accuracy:2 %(90~99%), 3 %(70~89%),unspecified (0~69%)

Pulse Rate 

Measuring and Alarm Range:30~250bpm

Resolution: 1bpm

Accuracy: 1bpm

NIBP 

Measurement object: Adult, Pediatric

Method: Oscillometric

Mode: Manual, Auto, STAT

Measuring Interval in AUTO Mode: 1, 2, 3, 5, 10, 15, 20, 30, 45, 60 (min)

Measuring Period in STAT Mode: 5 min

Cuff Pressure Range:0 ~300mmHg

Pulse Rate Range:30~250bpm

Measurement Rage: Adult 30~255mmHg, Pediatric 30~160mmHg

Over-pressure Protection: Adult 300mmHg, Pediatric 220mmHg

Pressure Resolution : 1mmHg

Temperature

Input: Body surface thermal-sensitive resistor temperature sensor

Measuring Range: 0~50℃

Accuracy: 0.1℃

5. Storage and Review 

Maximum Data Quantity: 3888 groups

 

Copyright © 2004- ORCHID MEDICAL All Rights Reserved.