12.1" Patient Monitor ORC-9000


*Option: TOUCH Screen available

More details


 

12.1" color TFT screen 
Multi‐channel display 
Big font interface
ST and arrhythmia analysis
Drug dose calculation and titration table
OxyCRG dynamic view display
Respiration monitoring with apnea alarms
 
Alarm review, arrhythmia review 
Patient info. Input 
Anti‐defibrillation design
NIBP over pressure protection
Plug‐in rechargeable battery, AC/DC available. 
Supporting wire or wireless network.
Technical Specifications
ECG
Lead Mode                          5 Leads (R, L, F, N, C or RA, LA, LL, RL,V) 
Lead selection                     I, II, III, avR, avL, avF, V
Wavef orm                          2 ch
Lead mode                          3 Leads ( R, L, F or RA, LA, LL) 
Lead selection                     I, II, III,
Wave form                          1 ch
Gain                               2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto
HR and Alarm Range                 Adult    15 ~ 300 bpm
                                   Neo/Ped    15 ~ 350 bpm
Accuracy                           ±1% or±1bpm, which is greater
Resolution                         1 bpm 
Sensitivity                        > 200 (uVp-p) 
Differential Input Impedance       > 5 MΩ
CMRR                   Monitor > 105 dB 
                                   Operation > 105 dB 
                                   Diagnosis > 85 dB
Electrode offset potential         ±300mV 
Leakage Current                    < 10 uA
Baseline Recovery                  < 3 S After Defi. 
ECG Signal Range                   ±8 m V ( Vp-p ) 
Bandwidth                           Surgery    1 ~ 20 Hz
                                    Monitor     0.5 ~ 40 Hz
                                    Diagnostic  0.05 ~ 130 Hz
Calibration Signal                  1 (mVp-p),  Accuracy:5%
ST Segment Monitoring Range         Measure and Alarm -2.0 ~ +2.0 mV
ARR Detecting                       Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS,
                                          PNP, PNC,Alarm Available,Review Available
Respiration
Method                           Impedance between R-F(RA-LL)
Differential Input Impedance       > 2.5 MΩ
Measuring Impedance Range          0.3~3 Ω
Base line Impedance Range           200~4 KΩ
Bandwidth                          0.1~2.5Hz
Resp. Rate                         Measuring and Alarm Range
                                    Adult 0 ~ 120 Brpm 
                                    Neo/Ped 0 ~ 150 Brpm 
                                    Resolution 1 Brpm 
                                    Accuracy ±2 Brpm
Apnea Alarm                        10 ~ 40 S
 
NIBP 
Method                            Oscillometric
Mode                              Manual, Auto, STAT                        
Measuring Interval in AUTO Mode  1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)
Measuring Period in STAT Mode     5 Min
Pulse Rate Range          40 ~ 240 bpm
Alarm Type                 SYS, DIA, MEAN
Measuring and alarm range        Adult Mode
                                    SYS 40 ~ 270 mmHg 
                                    DIA 10 ~ 215 mmHg 
                                    MEAN 20 ~ 235 mmHg
                                Pediatric Mode
                                    SYS 40 ~ 200 mmHg 
                                    DIA 10 ~ 150 mmHg 
                                    MEAN 20 ~ 165 mmHg
                                Neonatal Mode
                                    SYS 40 ~ 135 mmHg 
                                    DIA 10 ~ 100 mmHg 
                                    MEAN 20 ~ 110 mmHg
Resolution                      1mmHg
Accuracy                        Maximum Mean error ±5mmHg
                                Maximum Standard deviation ±8mmHg
Overpressure Protection          Adult Mode 297±3 mmHg 
                                 Pediatric Mode 240±3 mmHg 
                                 Neonatal Mode 147±3 mmHg
SpO2
Measuring Range                  0 ~ 100 % 
Alarm Range                      0 ~ 100 % 
Resolution                       1 %
Accuracy                         70% ~ 100%  2 %
                                 0%  ~  69% unspecified
Actualization intervalabout      1 Sec. 
Alarm Delay                      10 Sec.
Pulse Rate                       Measuring and Alarm Range 20~300 bpm
                                 Resolution       1bpm
                                 Accuracy ±3bpm
                                   
TEMP
Channel                          2
Measuring and Alarm Range 0 ~ 50 ℃
Resolution                      0.1 ℃
Accuracy                ±0.2 ℃
Actualization intervalabout     1 Sec.
Average Time Constant           < 10 Sec.
IBP
Label                           ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range       ART 0 ~ 300 mmHg 
                                PA -6 ~ 120 mmHg
                                CVP/RAP/LAP/ICP-10 ~ 40 mmHg
                                P1 / P2-10 ~ 300 mmHg 
Press Sensor                    Sensitivity 5  uV/V/mmHg
                                Impedance 300-3000Ω
Resolution                      1 mmHg
Accuracy                        ±2% or 1mmHg which is greater
Actualization interval        about 1 secretary
   
 
Standard:  ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
Optional:  Nellcor SpO2, EtCO 2, IBP, Thermal Recorder

*12.1" color TFT screen 

*Multi‐channel display 

*Big font interface

*ST and arrhythmia analysis

*Drug dose calculation and titration table

*OxyCRG dynamic view display

*Respiration monitoring with apnea alarms,Alarm review, arrhythmia review 

*Patient info. Input 

*Anti‐defibrillation design

*NIBP over pressure protection

*Plug‐in rechargeable battery, AC/DC available. 

*Supporting wire or wireless network.


Technical Specifications


ECG

Lead Mode                          5 Leads (R, L, F, N, C or RA, LA, LL, RL,V) 

Lead selection                     I, II, III, avR, avL, avF, V

Wavef orm                          2 ch

Lead mode                          3 Leads ( R, L, F or RA, LA, LL) 

Lead selection                     I, II, III,

Wave form                          1 ch

Gain                               2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto

HR and Alarm Range                 Adult    15 ~ 300 bpm

                                   Neo/Ped    15 ~ 350 bpm

Accuracy                           ±1% or±1bpm, which is greater

Resolution                         1 bpm 

Sensitivity                        > 200 (uVp-p) 

Differential Input Impedance       > 5 MΩ

CMRR                   Monitor > 105 dB 

                                   Operation > 105 dB 

                                   Diagnosis > 85 dB

Electrode offset potential         ±300mV 

Leakage Current                    < 10 uA

Baseline Recovery                  < 3 S After Defi. 

ECG Signal Range                   ±8 m V ( Vp-p ) 

Bandwidth                           Surgery    1 ~ 20 Hz

                                    Monitor     0.5 ~ 40 Hz

                                    Diagnostic  0.05 ~ 130 Hz

Calibration Signal                  1 (mVp-p),  Accuracy:5%

ST Segment Monitoring Range         Measure and Alarm -2.0 ~ +2.0 mV

ARR Detecting                       Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS,

                                          PNP, PNC,Alarm Available,Review Available


Respiration

Method                           Impedance between R-F(RA-LL)

Differential Input Impedance       > 2.5 MΩ

Measuring Impedance Range          0.3~3 Ω

Base line Impedance Range           200~4 KΩ

Bandwidth                          0.1~2.5Hz

Resp. Rate                         Measuring and Alarm Range

                                    Adult 0 ~ 120 Brpm 

                                    Neo/Ped 0 ~ 150 Brpm 

                                    Resolution 1 Brpm 

                                    Accuracy ±2 Brpm

Apnea Alarm                        10 ~ 40 S

 

NIBP 

Method                            Oscillometric

Mode                              Manual, Auto, STAT                        

Measuring Interval in AUTO Mode  1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)

Measuring Period in STAT Mode     5 Min

Pulse Rate Range          40 ~ 240 bpm

Alarm Type                 SYS, DIA, MEAN

Measuring and alarm range        Adult Mode

                                    SYS 40 ~ 270 mmHg 

                                    DIA 10 ~ 215 mmHg 

                                    MEAN 20 ~ 235 mmHg

                                Pediatric Mode

                                    SYS 40 ~ 200 mmHg 

                                    DIA 10 ~ 150 mmHg 

                                    MEAN 20 ~ 165 mmHg

                                Neonatal Mode

                                    SYS 40 ~ 135 mmHg 

                                    DIA 10 ~ 100 mmHg 

                                    MEAN 20 ~ 110 mmHg

Resolution                      1mmHg


Accuracy                        Maximum Mean error ±5mmHg

                                Maximum Standard deviation ±8mmHg

Overpressure Protection          Adult Mode 297±3 mmHg 

                                 Pediatric Mode 240±3 mmHg 

                                 Neonatal Mode 147±3 mmHg


SpO2

Measuring Range                  0 ~ 100 % 

Alarm Range                      0 ~ 100 % 

Resolution                       1 %

Accuracy                         70% ~ 100%  2 %

                                 0%  ~  69% unspecified

Actualization intervalabout      1 Sec. 

Alarm Delay                      10 Sec.

Pulse Rate                       Measuring and Alarm Range 20~300 bpm

                                 Resolution       1bpm

                                 Accuracy ±3bpm                               

TEMP

Channel                          2

Measuring and Alarm Range 0 ~ 50 ℃

Resolution                      0.1 ℃

Accuracy                ±0.2 ℃

Actualization intervalabout     1 Sec.

Average Time Constant           < 10 Sec.

 

IBP

Label                           ART, PA, CVP, RAP, LAP, ICP, P1, P2

Measuring and alarm range       ART 0 ~ 300 mmHg 

                                PA -6 ~ 120 mmHg

                                CVP/RAP/LAP/ICP-10 ~ 40 mmHg

                                P1 / P2-10 ~ 300 mmHg 

Press Sensor                    Sensitivity 5  uV/V/mmHg

                                Impedance 300-3000Ω

Resolution                      1 mmHg

Accuracy                        ±2% or 1mmHg which is greater

Actualization interval        about 1 secretary

Standard:  ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature

Optional:  Nellcor SpO2, EtCO 2, IBP, Thermal Recorder


 

 