15" TFT Patient Monitor ORC-9000D


ORC-9000D 15" Color TFT Display Multi-parameter Patient Monitor

More details


 

15" color TFT screen Multi-channel display Big font interface
ST and arrhythmia analysis
Drug dose calculation and titration table
OxyCRG dynamic view display
Respiration monitoring with apnea alarms
 
Alarm review, arrhythmia review
Patient info. Input
Anti-defibrillation design
NIBP over pressure protection
Plug-in rechargeable battery, AC/DC available. Supporting wire or wireless network.
ECG
Lead mode               5 Leads, I, II, III, AVR, AVL, AVF, V
Gain                   ×2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV,auto
Heart rate             Measure range:
                        Adult    15 ~ 300 bpm
                        Neonatal/Pediatric 15 ~ 350 bpm
Accuracy                ±1% 
Resolution              1 bpm 
Sensitivity             > 200 VμP-P 
Differential Input Impedance      > 5 M ohm
CMRR                       Monitor Mode   >100 dB 
                               Surgery Mode >100 dB 
                               Diagnostic Mode  >90 dB
Electrode offset potential     ±300mV 
Leakage Current                < 10 μA
PACE pulse detect              range±2~±700mV
                               width 0.1~2ms
                               rise time 10~100 μs
PACE pulse rejection           range ±2 ~±700mV
                               width 0.1~2ms
                               rise time 10 ~100 μs 
Baseline Recovery              < 3 s  After defibrillation. 
Signal Range                   ±8 mV p-p
Bandwidth       Surgery      1 ~ 20 Hz 
                               Monitor 0.5 ~ 40 Hz 
                               Diagnostic   0.05 ~ 130 Hz
Calibration Signal             1 mV p-p, 5% accuracy
ST measurement                 Range -2.0 ~+2.0 mV 
                               Accuracy-0.8mV~+0.8mV
                               ±0.02mV or±10%, which is greater
                               Other range: unspecified
Respiration
Method                         Impedance between RA-LL
Differential Input Impedance   >2.5 MΩ
Respiration Impedance Range     0.3~3Ω
Base Impedance Range           200Ω~4000Ω
Bandwidth                     0.1 ~ 2.5 Hz
Gain                          ×0.25,×0.500,×1,×2,×4
Respiration Rate               Measurement Range
                               Adult 0 ~ 120 BrPM
                               Neonatal / Pediatric 0 ~ 150 BrPM 
Resolution                     1 BrPM
Accuracy               0~6 BrPM: unspecified
                      7~150 BrPM:±2 BrPM or±2%
                      use the greater
Inspiriting current       < 300     A RMS max
Apnea Alarm               10 ~ 40 s
NIBP
Method                            Oscillometry 
Measure mode                      Manual, Auto, Continual
Measure Interval in AUTO Mode     1,2,3,4,5,10,15,30,60,90,120,180,240,480 min
Measure Period in Continual Mode    5 min
Pulse Rate Range               40 ~ 240 bpm
Measure and Alarm Range        Adult Mode
                                 SYS 40 ~ 270 mmHg 
                                 DIA 10 ~ 215 mmHg 
                                 MEAN20 ~ 235 mmHg
                               Pediatric Mode
                                 SYS 40 ~ 220 mmHg  
                                 DIA 10 ~ 150 mmHg 
                                 MEAN20 ~ 165 mmHg
                               Neonatal Mode
                                 SYS 40 ~ 135 mmHg 
                                 DIA 10 ~ 100 mmHg 
                                 MEAN 20 ~ 110 mmHg
Static pressure accuracy       ±3mmHg
Resolution                     1mmHg
Accuracy                       Maximum Mean error  ±5mmHg
                               Maximum Standard deviation     8mmHg
Overpressure Protection        Adult 297±3 mmHg 
                               Pediatric 240±3 mmHg 
                               Neonatal 147±3 mmHg
SpO2
Measurement Range              0 ~ 100 %
Resolution                     1 %
Accuracy                      70% ~ 100% ±2 %
                              69%
                              0% ~ 39%  unspecified
Pulse Rate                    Measure and Alarm Range 20~300bpm
                              Resolution 1bpm
                              Accuracy ±3bpm
TEMP
Channel                       2
Measure and Alarm Range       0 ~ 50℃
Resolution                    0.1℃
Accuracy(no sensor)           ±0.1(25℃-45℃),0.2±℃(other)
Accuracy(include sensor)      ±0.2℃(32℃-42℃)
                     ±0.3(other)
tandard:  ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
Optional:  EtCO2, IBP, Thermal Recorder

*15" color TFT screen Multi-channel display Big font interface

*ST and arrhythmia analysis

*Drug dose calculation and titration table

*OxyCRG dynamic view display

*Respiration monitoring with apnea alarms

 *Alarm review, arrhythmia review

*Patient info. Input

*Anti-defibrillation design

*NIBP over pressure protection

*Plug-in rechargeable battery, AC/DC available. Supporting wire or wireless network.


ECG

Lead mode               5 Leads, I, II, III, AVR, AVL, AVF, V

Gain                   ×2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV,auto

Heart rate             Measure range:

                        Adult    15 ~ 300 bpm

                        Neonatal/Pediatric 15 ~ 350 bpm

Accuracy                ±1% 

Resolution              1 bpm 

Sensitivity             > 200 VμP-P 

Differential Input Impedance      > 5 M ohm

CMRR                       Monitor Mode   >100 dB 

                               Surgery Mode >100 dB 

                               Diagnostic Mode  >90 dB

Electrode offset potential     ±300mV 

Leakage Current                < 10 μA

PACE pulse detect              range±2~±700mV

                               width 0.1~2ms

                               rise time 10~100 μs

PACE pulse rejection           range ±2 ~±700mV

                               width 0.1~2ms

                               rise time 10 ~100 μs 

Baseline Recovery              < 3 s  After defibrillation. 

Signal Range                   ±8 mV p-p

Bandwidth       Surgery      1 ~ 20 Hz 

                               Monitor 0.5 ~ 40 Hz 

                               Diagnostic   0.05 ~ 130 Hz

Calibration Signal             1 mV p-p, 5% accuracy

ST measurement                 Range -2.0 ~+2.0 mV 

                               Accuracy-0.8mV~+0.8mV

                               ±0.02mV or±10%, which is greater

                               Other range: unspecified

 

Respiration

Method                         Impedance between RA-LL

Differential Input Impedance   >2.5 MΩ

Respiration Impedance Range     0.3~3Ω

Base Impedance Range           200Ω~4000Ω

Bandwidth                     0.1 ~ 2.5 Hz

Gain                          ×0.25,×0.500,×1,×2,×4

Respiration Rate               Measurement Range

                               Adult 0 ~ 120 BrPM

                               Neonatal / Pediatric 0 ~ 150 BrPM 

Resolution                     1 BrPM

Accuracy               0~6 BrPM: unspecified

                      7~150 BrPM:±2 BrPM or±2%

                      use the greater

Inspiriting current       < 300     A RMS max

Apnea Alarm               10 ~ 40 s

 

NIBP

Method                            Oscillometry 

Measure mode                      Manual, Auto, Continual

Measure Interval in AUTO Mode     1,2,3,4,5,10,15,30,60,90,120,180,240,480 min

Measure Period in Continual Mode    5 min

Pulse Rate Range               40 ~ 240 bpm

Measure and Alarm Range        Adult Mode

                                 SYS 40 ~ 270 mmHg 

                                 DIA 10 ~ 215 mmHg 

                                 MEAN20 ~ 235 mmHg

                               Pediatric Mode

                                 SYS 40 ~ 220 mmHg  

                                 DIA 10 ~ 150 mmHg 

                                 MEAN20 ~ 165 mmHg

                               Neonatal Mode

                                 SYS 40 ~ 135 mmHg 

                                 DIA 10 ~ 100 mmHg 

                                 MEAN 20 ~ 110 mmHg

Static pressure accuracy       ±3mmHg

Resolution                     1mmHg

Accuracy                       Maximum Mean error  ±5mmHg

                               Maximum Standard deviation     8mmHg

Overpressure Protection        Adult 297±3 mmHg 

                               Pediatric 240±3 mmHg 

                               Neonatal 147±3 mmHg

SpO2

Measurement Range              0 ~ 100 %

Resolution                     1 %

Accuracy                      70% ~ 100% ±2 %

                              69%

                              0% ~ 39%  unspecified


Pulse Rate                    Measure and Alarm Range 20~300bpm

                              Resolution 1bpm

                              Accuracy ±3bpm


TEMP

Channel                       2

Measure and Alarm Range       0 ~ 50℃

Resolution                    0.1℃

Accuracy(no sensor)           ±0.1(25℃-45℃),0.2±℃(other)

Accuracy(include sensor)      ±0.2℃(32℃-42℃)

                     ±0.3(other)


Standard:  ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature

Optional:  EtCO2, IBP, Thermal Recorder

 