• English English

Categories

Contact Info

Tel:  0086-25-84055220, 
      0086-25-66920771      
Fax:  0086-25-84055220
Email: info@orchid-med.com
       orchidmed@foxmail.com
   

  • orchidmed@hotmail.com-Click To Talk
  • orchidmed-Click To Talk
  • sales@orchid-med.com-Send Email to me!

Infusion Pump ORC-900



 

Infusion Pump  
OIP-900
Large LCD display, with backlight, suitable for working in various ambient light conditions.
Disposable IV set of any brand is suitable for this pump
Three working modes: Rate/Volume/Time mode
Purge, KVO function
Heating function is optional, suitable for infusing in winter or there is requirement for the medication temperature. 
Remote Controller makes operating more convenient.
Central monitoring system is optional, the infusing status of each pump is displayed in real time at the central station through wireless transmission.
Simple and convenient in operating, intuitive presence of working status.
Audible and Visible alarms
Alarm: Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle.
Size: 188 mm(L)*198 mm(W)*228 mm(H)
Net Weight: 2.2kg
Technical Specifications
 
Pump Type:  Drip type infusion pump
Pumping Way: Peristalic fingers
Adjustable Drop Rate Range: 1~400 drops/min (step: 1 drop/min)
Adjustable Volume Rate Range:1~1200 ml/h (when 1~99.9 ml/h, step: 0.1 ml/h; greater than 99.9 ml/h, step: 1 ml/h)
Flow Precision:Within±3% (using the IV set appointed by the manufacturer or calibrated high quality IV set) Mechanical precision: within±2%.
Purge Rate:800 ml/h
KVO Rate:1 ml/h (1~300 ml/h);
         3 ml/h (greater than 300 ml/h); 
Infusion Volume Range: 1 ml~9999.9 ml (step: 0.1 ml)
Maximum Accumulated Volume:9999.9 ml (step: 0.1 ml)
Time Range:1 min~9999 min (step: 1 min)
Occlusion Alarm Threshold: High: 800 mmHg±200 mmHg (106.7kPa±26.7kPa) 
                           Medium: 500 mmHg±100 mmHg (66.7kPa±13.3kPa) 
                           Low: 300 mmHg±100 mmHg (40.7kPa±13.3kPa)
Alarm: Infusion Complete, Empty, Faulty Signal, Misoperation,
        Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle.
Air Bubble Detector: Method: ultrasonic wave, sensitivity: ≧25 μL
Fuse: F1AL/250V ("F" indicate fast,"L" indicate low breaking capacity),
      2 pcs (installed inside pump). 
Power Supply:  AC 85~265V, 50/60Hz;
Internal Battery:11.1V rechargeable li-ion battery. Capacity:≧2000mAh;
                 the pump can work more than 4 hours at the flow rate of 25 ml/h after charging for
                 8 hours (Medium rate specified by GB 9706.27-2005). 
Power: ≦40VA
Size:  188 mm(L)*198 mm(W)*228 mm(H) 
Weight: 2.2KG
Environment Requirements:  Transport
                           Ambient Temperature: -30℃~+55℃
                           Relative Humidity: 20%~95% (non-condensing) 
                           Atmosphere Pressure: 70kPa~106kPa
                           Storage
                           Ambient Temperature: -30℃~+55℃
                           Relative Humidity: 20%~95% 
                           Atmosphere Pressure: 70kPa~106kPa 
                           Operation
                           Ambient Temperature: +5~+40℃
                           Relative Humidity: 20%~90% 
                           Atmosphere Pressure: 86kPa~106kPas
Calibration function, disposable IV set of any brand is suitable for this pump. Three working modes: Rate/Volume/Time mode.
Alarm: Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle.
Purge, KVO function
Heating function , suitable for infusing in winter or there is requirement for the fluid medication temperature.
Remote Controller 
makes operating more convenient.
infusion monitoring system (Optional),
the status of each pump is displayed in real time at the central station through wireless transmission.
4.3 inch color LCD display, with backlight, suitable for working in various ambient light conditions.
Display time, battery, infusing status, mode, rate, target volume, accumulated volume, target volume, sound volume, pressure, department, bed No., I/V set, temperature of medication
Drip Detector.
Infusion Stand (Optional)

Large LCD display, with backlight, suitable for working in various ambient light conditions.

Disposable IV set of any brand is suitable for this pump

Three working modes: Rate/Volume/Time mode

Purge, KVO function

Heating function is optional, suitable for infusing in winter or there is requirement for the medication temperature. 

Remote Controller makes operating more convenient.

Central monitoring system is optional, the infusing status of each pump is displayed in real time at the central station through wireless transmission.

Simple and convenient in operating, intuitive presence of working status.

Audible and Visible alarms

Alarm: Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle.

 

Size: 188 mm(L)*198 mm(W)*228 mm(H)

Net Weight: 2.2kg

 

 

Technical Specifications

 

Pump Type:  Drip type infusion pump

Pumping Way: Peristalic fingers

Adjustable Drop Rate Range: 1~400 drops/min (step: 1 drop/min)

Adjustable Volume Rate Range:1~1200 ml/h (when 1~99.9 ml/h, step: 0.1 ml/h; greater than 99.9 ml/h, step: 1 ml/h)

Flow Precision:Within±3% (using the IV set appointed by the manufacturer or calibrated high quality IV set) Mechanical precision: within±2%.

Purge Rate:800 ml/h

KVO Rate:1 ml/h (1~300 ml/h);

         3 ml/h (greater than 300 ml/h); 

Infusion Volume Range: 1 ml~9999.9 ml (step: 0.1 ml)

Maximum Accumulated Volume:9999.9 ml (step: 0.1 ml)

Time Range:1 min~9999 min (step: 1 min)

Occlusion Alarm Threshold: High: 800 mmHg±200 mmHg (106.7kPa±26.7kPa) 

                           Medium: 500 mmHg±100 mmHg (66.7kPa±13.3kPa) 

                           Low: 300 mmHg±100 mmHg (40.7kPa±13.3kPa)

Alarm: Infusion Complete, Empty, Faulty Signal, Misoperation,

        Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle.

Air Bubble Detector: Method: ultrasonic wave, sensitivity: ≧25 μL

Fuse: F1AL/250V ("F" indicate fast,"L" indicate low breaking capacity),

      2 pcs (installed inside pump). 

Power Supply:  AC 85~265V, 50/60Hz;

Internal Battery:11.1V rechargeable li-ion battery. Capacity:≧2000mAh;

                 the pump can work more than 4 hours at the flow rate of 25 ml/h after charging for

                 8 hours (Medium rate specified by GB 9706.27-2005). 

Power: ≦40VA

Size:  188 mm(L)*198 mm(W)*228 mm(H) 

Weight: 2.2KG

Environment Requirements:  Transport

                           Ambient Temperature: -30℃~+55℃

                           Relative Humidity: 20%~95% (non-condensing) 

                           Atmosphere Pressure: 70kPa~106kPa

                           Storage

                           Ambient Temperature: -30℃~+55℃

                           Relative Humidity: 20%~95% 

                           Atmosphere Pressure: 70kPa~106kPa 

                           Operation

                           Ambient Temperature: +5~+40℃

                           Relative Humidity: 20%~90% 

                           Atmosphere Pressure: 86kPa~106kPas

 

Calibration function, disposable IV set of any brand is suitable for this pump. Three working modes: Rate/Volume/Time mode.

Alarm: Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle.

Purge, KVO function

 

Heating function , suitable for infusing in winter or there is requirement for the fluid medication temperature.

 

Remote Controller 

makes operating more convenient.

 

infusion monitoring system (Optional),

the status of each pump is displayed in real time at the central station through wireless transmission.

 

4.3 inch color LCD display, with backlight, suitable for working in various ambient light conditions.

Display time, battery, infusing status, mode, rate, target volume, accumulated volume, target volume, sound volume, pressure, department, bed No., I/V set, temperature of medication

 

Drip Detector.

 

Infusion Stand (Optional)

 

 

 

 

 

Copyright © 2004- ORCHID MEDICAL All Rights Reserved.