OBW-220T Infant Radiant Warmer



Functions:
☆Microprocessor based servo controlled temperature system.
☆The microprocessor-controlled unit allows for three settings: pre-warm, manual or automatic.
☆Alarm functions for safety includes:
 Power failure; Temperature deviation; Temperature sensor failure; Over temperature;
☆APGAR timer to record therapy time
☆Convenient X-ray cassette under infant bed
☆Heater head can be adjusted  + 90º horizontally
☆Tilt angle of infant bed is adjustable
☆Observe light angle is adjustable
☆Transparent protector folded
☆Adopts anti-explosion micro crystal quartz infrared radiation tube for its radiation source,the heating is quick and life-span is long
☆Alarms are audible and visual
☆A second thermal cut-out function for more safety
☆Skin temperature sensor failure protect function avoid over temperature
☆Temperature deviation can be amended in front panel directly
☆Low pressure aspirator, oxygen supply system and LED phototherapy unit

Technical data:                 
 1.Power supply : 110/220V   60/50Hz
 2.  Power input: ≤1200VA
 3. Operating condition:
    An ambient Temperature:18℃-30℃
    An ambient Relative Humidity: 30%--75%RH
    Atmospheric Pressure: 700~1060 hPa
    An ambient Air Velocity <0.3m/s
 4. Temperature control: 32℃~38℃
 5.Temperature control accuracy: ≤0.5℃
 6.Mattress temperature uniformity : <2℃
 7.Skin temperature sensor accuracy: + 0.3℃
 8.Warm-up time: ≤30min
 9. Infant Bed tilt angle:+ 10°
 10.APGAR timer range: ≤24h
 11.Heater head horizontal: ±90°
 12.Mattress size: 67cm× 54cm
 13.Distance from heater to mattress:80cm
 14.Height adjustable range:0-20cm
 15.LED phototherapy light: 2pcs × 8W

Standard configuration:
 Main body (including the radiant source, control system, infant bed, bracket), X-ray cassette , Observe light , I.V.pole, skin temperature sensor, tray, mattress, transparent protector, castors. LED phototherapy unit ,low pressure aspirator; oxygen supply system.

Optional parts:
  Drawer,;  RS-232(485) connector;

Transport and storage:
 Environment Temperature:-40℃~ +55℃
 Environment Relative Humidity: ≤95%
 Atmospheric Pressure: 500~1060hPa

Package:
 Each unit is packed one case
  Size:135cm×85cm × 98cm
  Gross weight: ≤170kg