Features:
■ The whole running process of the equipment is controlled
by a computer . Also ,automatic electric potential
tracking and correcting software are adopted to
ensure its stable performance.
■ The machine adopts innovative international patent
technology such as wave theory flushing method and
direct flushing pipe method to avoid block and crossed
contamination.
■ Every time putting the specimen into the machine,the
machine could simultaneously detect eight ions including
K, Na, Cl, iCa, Nca,TCa, pH, Li,TCO2, AG as
well as ten parameterS.
It can absorb the specimen and calibrate the ion automatically , and make analysis quickly. It only takes 25s
to finish the process of absorbing the specimen to indicating the result.
■ After conducting analysis to specimens, the equipment will automatically flush , keeping the electrode
standby in clean status.
■ It has a ult5a large screen with completely Chinese display ,which is quite clear for operators.The built-in
printer can print out the result ,so it's very quick and convenient.
■ The equipment is set with quality control correction procedure, and capable of correcting measured date
automatically,as well as by the two parameters of pitch and average deviation.
■ The equipment is capable of storing 1000 result, and it can be extended to be more than 10000. The equipment
will automatically refresh once it reaches the store limit .
■ The equipment features power failure protection function.It can still store quality control and specimen data
upon power failure.The storing time exceeds 5years.
■ The equipment can work 24 hours a day . If there is no operation for a long time , the equipment will change
into standby state, making it accessible at any time .It is quite suitable for large/middle size hospitals of
many emergency calls and specimens.
■ The equipment can be powered off at any time and greatly save reagent.It is also suitable for private hospital
and hospital of county and town level since two hospitals are of less specimen quantities.
Specification
■ Range and accuracy of measurement:
|
Range of Measurement |
Resolution |
Accuracy of measurement |
K+
|
0.5~15.0mmol/L |
0.01mmol/L |
≤1.0% |
Na+
|
30~200mmol/L |
0.1mmol/L |
≤1.0% |
Cl-
|
20~200mmol/L |
0.1mmol/L |
≤1.0% |
Ca++
|
0.1~6.0mmol/L |
0.01mmol/L |
≤1.5% |
Li+
|
0.2~5.0mmol/L |
0.01mmol/L |
≤2.0% |
pH
|
4~9pH |
0.01pH |
≤0.5% |
TCO2 |
2.0~70.0mmol/L |
0.1mmol/L |
≤3.0% |
Applicable specimens:blood serum,blood p;asma,whole blood,cerebrospinal fluid and dilute urine
■ Quantity of specimens:60~300ul(item3 to item 10)
■ Ambient temperature:5~35℃
■ Velocity for measurement: ≤25S
■ Requirement on power supply:220V±10V 50Hz60Hz
■ Power rate:400W