• English English

Categories

Contact Info

Tel:  0086-25-84055220, 
      0086-25-66920771      
Fax:  0086-25-84055220
Email: info@orchid-med.com
       orchidmed@foxmail.com
   

  • orchidmed@hotmail.com-Click To Talk
  • orchidmed-Click To Talk
  • sales@orchid-med.com-Send Email to me!

12 Channels ECG (ORC-12A)



Features:

(1) Portable 12 channel ECG machine

(2) Manual/Auto/Arrhythmia Analysis Modes

(3) Alphabetic keyboard for patient information

(4) Built in rechargable Li-Ion battery 14.4V(4400mAh)

(5) Adapt to 110-230V,50/60HZ AC power supply

(6) Real-time ECG waveform,cases save/replay

(7) Built in USB/RS232 interface(ECGNET software optional)

(8) Package:40cmx34cmx22cm   GW:5.9KG   NW:3.2KG

 ORC-12A:320X240graphic 5.7inch LCD,16cases save/replay

 

Specifications:

Lead:              Standard 12 leads

Acquisition:  Simultaneous 12 leads

Resolution:   12bit/1000Hz

Operation mode: Manual/Auto/Analysis Modes

Filter:          AC.EMG Filter

Drift filter: Anti-Drift System

CMRR:        ≥100dB,with AC Filter

Input circuit:      Floating,Protection against defibrillator effect

Input circuit current: ≤0.1µA

Input Impedance:         >50MΩ

Patient current leakage: <10µA

Calibrating voltage:         1mV±3%

Voltage tolerance:           ±500mV

Time constant:                 >3.2s

Frequent response:         0.05Hz~160Hz

Noise level:   ≤15µVp-p

Threshold:    ≤20µV

Paper speed: 25,50mm/s(±3%)

Sensitivity:   Auto,2.5,5,10,20,40mm/mV

Recorder:     High resolution thermal printer

Safety standard:  GB9706.1-2007,IEC Class I,Type CF

 

Features:
Lead: Standard 12 leads
Acquisition: Simultaneous 12 leads
Resolution: 12bit/1000Hz
Operation mode: Manual/Auto/Analysis Modes
Filter: AC.EMG Filter
Drift filter: Anti-Drift System
CMRR: ≥100dB, with AC Filter
Input circuit: Floating, Protection against defibrillator effect
Input circuit current: ≤0.1µA
Drift filter: Anti-Drift System
CMRR: ≥100dB, with AC Filter
Input circuit: Floating, Protection against defibrillator effect
Input circuit current: ≤0.1µA
Input Impedance: >50MΩ
Patient current leakage: <10µA
Calibrating voltage: 1mV±3%
Voltage tolerance: ±500mV
Time constant: >3.2s
Frequent response: 0.05Hz~160Hz
Noise level: ≤15µVp-p
Threshold: ≤20µV
Paper speed: 25, 50mm/s (±3%)
Sensitivity: Auto, 2.5, 5, 10, 20, 40mm/mV
Recorder: High resolution thermal printer
Safety standard: GB9706.1-2007, IEC Class I, Type CF
Specifications:
Portable 12 channel ECG machine
Manual/Auto/Arrhythmia Analysis Modes
Alphabetic keyboard for patient information
Built in rechargable Li-Ion battery 14.4V (4400mAh)
Adapt to 110-230V, 50/60HZ AC power supply
Real-time ECG waveform, cases save/replay
Built in USB/RS232 interface (ECGNET software optional)
Package: 40cm×34cm×22cm   GW: 5.9KG   NW: 3.2KG
320×240 graphic 5.7inch LCD, 16cases save/repla
Copyright © 2004- ORCHID MEDICAL All Rights Reserved.