ORC-680C Anesthesia Machine



Anesthesia Machine

Main body:      High-strength engineering plastic rack, light, beautiful and corrosion resistant

Scope of application:       adult, child

Gas source:               O2: 0.27~0.55MPa  N2O: 0.27~0.55MPa

Flow meter:                O2: 0.1~10L/min    N2O: 0.1~10L/min

■O2, N2O linkage and N2O Stopper:    When using nitrous oxide, oxygen concentration>25%;

 When the oxygen pressure<0.2MPa, the flow of nitrous oxide would be cut off.

Flow rate of rapid oxygen supply:  25~75L/min

Low oxygen pressure alarm:    There will be sound alarm when the oxygen pressure < 0.2MPa

Vaporizer: It has the function of automatic compensation based on pressure, temperature, and flow rate.

 The regulation range of evaporator concentration is 0~5 vol%. Among Halothane, Enflurane,

Isoflurane and Sevoflurane, one can be chosen for application as required by the customer. And

vaporizers that are imported with original packaging are also available.

Respiratory circuit:  working mode: all-close, semi-close, semi-open;   releasing pressure: 1-4 kPa

Respiratory bellows:   bellows for adults, bellows for children;  tidal volume range:0~1,500 ml

******************************************************************************************

Ventilator

Display mode:               High-definition 5.7” LCD screen display

Ventilation mode:            IPPV,SIPPV,SIMV,PEE,MANUAL,SIGH

Ventilation parameters:       Tidal volume:          50~1500ml

Rate:                 2~99bmp

SIMV rate:                 2~20bpm

I:E:                  2:1~1:8

Inspiratory trigger pressure: -1.0~2.0 kPa

PEEP:                0~2.0 kPa

Pressure range:         1.0~6.0 kPa

SIGH:    1.5 times the inspiratory time

Parameters for ventilation monitoring:  

tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of

airway, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure

(oxygen concentration)

Security Alarm System:

Oxygen Concentration alarm:    upper limit setting range (50%~100%)

low limit setting range  (15%~50%)

Airway pressure alarm:         upper limit setting range  1.0~6.0 kPa

low limit setting range   0.4~2.0 kPa

Per-minute ventilation volume alarm:  upper limit setting range  3.0~30L/min

low limit setting range   1.0~10L/min

Sustained high-pressure alarm:     it will give alarm when stress have consistently

been higher than 2.5 kPa

Suffocation alarm:             it will give sound and light alarm if there is

no tidal volume input for 15 seconds

Power alarm

■    Power:                       AC 220V±10%     50Hz±1Hz

                            (UPS, Storage battery)

*Items within brackets are optional.