• English English

Categories

Contact Info

Tel:  0086-25-84055220, 
      0086-25-66920771      
Fax:  0086-25-84055220
Email: info@orchid-med.com
       orchidmed@foxmail.com
   

  • orchidmed@hotmail.com-Click To Talk
  • orchidmed-Click To Talk
  • sales@orchid-med.com-Send Email to me!

ORC-2400 Infusion Pump



CHARACTERISTICS :

Compatible with  IV sets of any Brand with high accuracy. Automatical calibration for IV sets of any Brand. Three working modes: Drop counting control,Rate control  and time control mode. 8 Hours internal battery life in high capacity. Has a unique color LCD and an internal battery with a high capability. Swith between ml/h and drops/min freely.
Three levels of alarm volume: high, medium and low.
Three levels of Occlusion pressure: high, medium and low.
KVO function: When finish the total volume of an infusion,   the pump will alarm and enter KVO state. 

****************************************************************

SPECIFICATIONS:

Controls: Drop counting and adjusting the delivery rate automatically
Pump Type: Peristaltic finger Applicable IV Sets: Compatible with IV sets of any standard(including lucifugal IV sets)
Accuracy: ≤25drop/min:±2%, >25drop/min:±3% (With the drop counting control mode)
±5% (With the rate control mode after the correct calibration)
Delivery Rate Range: 1~400drop/min(1drop/min step) 1.0ml/h~1200ml/h (1.0ml/h~99.9ml/h, 0.1ml/h step; >99.9ml/h, 1ml/h step)
Delivery Time Range: 1min~1999min (1 min step)
Volume Limit Range: 0~9999ml (1 ml step)
Total Volume Range: 1~9999ml (1 ml step)

 

 

 

 

 

 

Rapid injection: 600ml/h
KVO Rate:

 

600ml/h
KVO Rate: W hen the delivery rate≤10ml/h, KVO is  1 ml/h .   O therwise KVO is 3ml/h.
Alarms: Air-in-line, Infusion complete when limited volume has been set, Empty container, Occlusion, Door is open, waitting time Over, No drop been detected, Operational errors, Low battery, other device failures.
Power Supply: AC power supply: AC 100 to 240V±10%,50/60Hz;
Internal LI Battery: 11.1V, 2000mAh. 8 Hours of continous operation on a new fully charged battery with the rate of 20 drops/min.
Power Consumption: ≤25VA
Safety level: ClassⅠ, Type BF
Dimensions: 130mm(L)× 200mm(W) × 230mm(H)
Net Weight: Approximately. 2.5kg
Operating Conditions: Ambient temperature: 5 to 40℃ Relative humidity: 20 to 90%
Storage Conditions: Ambient temperature: -10 to 55℃ Relative humidity: 10 to 90%
Accessories: AC power line, Operational manual
Copyright © 2004- ORCHID MEDICAL All Rights Reserved.